N1914B: Typical applications and operating conditions — Frequency range

The N1914B specifies Frequency range of DC ~ 220 GHz (sensor dependent, incl. USB power sensors) and Power range of -70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent). Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-01-20 has been reviewed against the site product master data and expanded with the specification highlights and method index for model N1914B; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — N1914B
Instrument — N1914B
Frequency rangeDC ~ 220 GHz (sensor dependent, incl. USB power sensors)
Power range-70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent)
Channels1-4 (2 sensors + 2 USB)

The principal specifications of the N1914B follow the site product master data: Frequency range DC ~ 220 GHz (sensor dependent, incl. USB power sensors) and Power range -70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent). Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that Channels 1-4 (2 sensors + 2 USB) matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Frequency rangeDC ~ 220 GHz (sensor dependent, incl. USB power sensors)
Power range-70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent)
Channels1-4 (2 sensors + 2 USB)
Reading rateFAST 400 readings/s (single channel, E-Series); 200 readings/s dual
Settling time20 ms (10 dB step)
Absolute accuracy±0.02 dB (log), sensor dependent
Power reference1.00 mW @50 MHz, ±0.4% (NPL traceable)
DisplayHigh-resolution color LCD, single/split screen
Remote interfacesGPIB, USB, LAN (LXI-C); SCPI
Display outputVGA output (external monitor)
Dimensions212.6 x 88.5 x 348.3 mm
Ordering optionsC01/C02/C03 calibrator; 300/301 line cord; 1A7/A6J calibration; 908/909 rack kits; BV0007B BenchVue
Related Instruments & Equipment
N1914B
N1914BView details →
VNA400
VNA400View details →
RFS44
RFS44View details →
References
  • Specifications: site product master data (model N1914B)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)
N1914B Model page →