LCX: Automated integration and data logging

The LCX specifies Frequency range of LCX100 DC, 4 Hz-300 kHz; LCX200 DC, 4 Hz-500 kHz and Rdc accuracy of +/-0.1%. Using the ISO/IEC Guide 98-3 (expression of measurement uncertainty) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-06-02 has been reviewed against the site product master data and expanded with the specification highlights and method index for model LCX; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — LCX
Instrument — LCX
Frequency rangeLCX100 DC, 4 Hz-300 kHz; LCX200 DC, 4 Hz-500 kHz
Rdc accuracy+/-0.1%
Basic impedance accuracy+/-0.05%

The principal specifications of the LCX follow the site product master data: Frequency range LCX100 DC, 4 Hz-300 kHz; LCX200 DC, 4 Hz-500 kHz and Rdc accuracy +/-0.1%. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ISO/IEC Guide 98-3 (expression of measurement uncertainty) method index, confirm that Basic impedance accuracy +/-0.05% matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
ModelsLCX100 / LCX200
Frequency rangeLCX100 DC, 4 Hz-300 kHz; LCX200 DC, 4 Hz-500 kHz
Frequency extensionK201 to 1 MHz; K210 to 1 MHz (10 ohm) / 10 MHz (100 ohm)
Impedance range100 mohm-100 Mohm (100 ohm source); 10 mohm-100 ohm (10 ohm source)
Basic impedance accuracy+/-0.05%
Rdc accuracy+/-0.1%
Test signal voltage10 mV-10 V, limited by frequency and source impedance
Internal DC bias0 V to +10 V DC
Source impedance100 ohm or 10 ohm
Measured parametersZ, Y, R, X, C, L, D, Q, phase, turns ratio and more
InterfacesUSB, LAN
Size/weight362 x 99 x 357 mm; 2.7 kg
Ordering numbersLCX100 3629.8856.02; LCX200 3629.8856.03; K201 3630.1880.03; K210 3630.1900.03
Related Instruments & Equipment
LCX
LCXView details →
HMP4000
HMP4000View details →
DAQ970A
DAQ970AView details →
References
  • Specifications: site product master data (model LCX)
  • Method index: ISO/IEC Guide 98-3 (expression of measurement uncertainty)
LCX Model page →