DAQ970A: Method index and measurement uncertainty

The DAQ970A specifies Memory of 1 million readings and Scan rate of Up to 450 channels/s. Using the IEEE Std 1588 (precision time synchronisation) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-06-09 has been reviewed against the site product master data and expanded with the specification highlights and method index for model DAQ970A; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — DAQ970A
Instrument — DAQ970A
Memory1 million readings
Scan rateUp to 450 channels/s
DC voltage100 mV ~ 300 V, 5 ranges

The principal specifications of the DAQ970A follow the site product master data: Memory 1 million readings and Scan rate Up to 450 channels/s. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the IEEE Std 1588 (precision time synchronisation) method index, confirm that DC voltage 100 mV ~ 300 V, 5 ranges matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Built-in DMM6.5 digits (22 bit), 0.003% basic DCV accuracy
Scan rateUp to 450 channels/s
Channel capacityUp to 120 channels (3 slots x 9 modules)
DC voltage100 mV ~ 300 V, 5 ranges
AC voltage100 mV ~ 300 V, 3 Hz ~ 300 kHz (true RMS)
Resistance100 ohm ~ 1000 Mohm (2-wire/4-wire)
TemperatureThermocouples E/J/K/N/R/T; PT100 and 2.2/5/10 kohm thermistors
StrainDirect (2/4-wire) and bridge (quarter/half/full)
InterfacesUSB + LAN; GPIB on DAQ973A; SCPI
Memory1 million readings
Dimensions/weightBench 261.0 x 103.7 x 378.0 mm; 4.2 kg
Ordering optionsDAQ973A (+GPIB); Z54 ANSI Z540 cal; DAQM900A-909A modules; 11062A/34307A/34308A accessories
Related Instruments & Equipment
DAQ970A
DAQ970AView details →
HMP4000
HMP4000View details →
LCX
LCXView details →
References
  • Specifications: site product master data (model DAQ970A)
  • Method index: IEEE Std 1588 (precision time synchronisation)
DAQ970A Model page →