PNCS-1: Calibration and routine verification

The PNCS-1 specifies Output Frequency of 1 GHz nominal (±1.5 ppm rear-panel trim) and Harmonics of typ. -35 dBc. Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-03-02 has been reviewed against the site product master data and expanded with the specification highlights and method index for model PNCS-1; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — PNCS-1
Instrument — PNCS-1
Output Frequency1 GHz nominal (±1.5 ppm rear-panel trim)
Harmonicstyp. -35 dBc
Output Amplitude+10 dBm (±2 dB), 50 Ω SMA

The principal specifications of the PNCS-1 follow the site product master data: Output Frequency 1 GHz nominal (±1.5 ppm rear-panel trim) and Harmonics typ. -35 dBc. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that Output Amplitude +10 dBm (±2 dB), 50 Ω SMA matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Output Frequency1 GHz nominal (±1.5 ppm rear-panel trim)
Output Amplitude+10 dBm (±2 dB), 50 Ω SMA
SSB Phase Noise10 Hz: -82 / 1 kHz: -138 / 10 kHz: -147 / 1 MHz: -149 dBc/Hz (typ.)
Harmonicstyp. -35 dBc
Internal Architecture100 MHz ultra-low-noise OCXO → ×2 → filter → ×5 → 1 GHz SAW → +10 dBm amp
Power Supply4.5 W, AC/DC 13.5 V adapter
Related Instruments & Equipment
PNCS-1
PNCS-1View details →
VSG200
VSG200View details →
USRP-X410
USRP-X410View details →
References
  • Specifications: site product master data (model PNCS-1)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)