A test rack subsystem plus an anechoic chamber with multi-axis positioner, reflector and feed antenna, converting a spherical wave into a quasi-plane wave at close range.

The compact range antenna test system comprises a test cabinet subsystem and an anechoic chamber subsystem. The cabinet subsystem includes a vector network analyser, an industrial PC and a positioner controller; the chamber subsystem consists mainly of a microwave anechoic chamber, a multi-axis positioner, a reflector, a feed antenna and a feed support. The compact range turns the spherical wave radiated by the feed into a quasi-plane wave over a short distance after reflection, thereby satisfying the far-field conditions for antenna measurement. The system meets the need for high-accuracy measurement of performance parameters during antenna development, production and repair, and fully automates measurement of passive antenna pattern, sidelobe level and gain, and of active antenna EIRP and TRP. It is widely used in universities, research institutes and enterprises.
Rolled-edge reflector profile · Broadband feed with a stable phase centre · Integrated full-wave simulation and design optimisation based on the method of moments
The reflector uses a main reflector with a transition rolled-edge surface, achieving low edge diffraction and suiting high-accuracy testing of low-sidelobe antennas better than a serrated-edge reflector. Machining accuracy is high and quiet-zone quality is better; combined with a standard-band feed antenna it covers a wide band.
The feed is a standard-band broadband antenna with a stable phase centre, a stable amplitude taper, a rotationally symmetric radiation pattern and low cross-polarisation. Feed and feed support are designed as a single unit, so removal and replacement are quick and require no recalibration.
Compact footprint, all-weather operation
Cabinet + chamber design for fast deployment
Superior quiet zone for low-sidelobe precision
Stable phase-centre broadband feed, no re-cal
MoM-based integrated full-wave simulation
Pattern, sidelobe, gain, EIRP, TRP — full metrics
Send us the device under test, frequency range, sample size and site conditions. Our engineering team will provide an executable configuration during solution consulting and site planning.