N1914A
Pengukur Daya RF dan Uji RF: EPM-Series dual-channel average power meter: compatible with 8480/E9300/E4410/N8480/U2000/U8480 sensors, 9 kHz to 110 GHz (sensor dependent); ±0.02 dB (log) absolute accuracy, color split-screen LCD, GPIB/USB/LAN (LXI-C) with SCPI; expandable to 4 channels via optional USB port.
EPM-Series dual-channel average power meter compatible with 8480/E9300/E4410/N8480/U2000/U8480 sensors, 9 kHz to 110 GHz (sensor dependent), -70 to +44 dBm.
Absolute accuracy ±0.02 dB (logarithmic), color LCD with split-screen display, GPIB/USB 2.0/LAN (LXI-C) remote control with SCPI.
Expandable to 4 channels with the optional USB host port; 1 mW 50 MHz power reference factory-set to ±0.4%, traceable to NPL (UK).
Two sensor channels, expandable to 4 with USB sensors via option
8480/E9300/E4410/N8480/U2000/U8480/X-Series USB sensors
Up to 110 GHz with V/W-band waveguide sensors
±0.02 dB (log) or ±0.5% (linear) absolute accuracy
Single/split screen; any two of A, B, A-B, ratio displayed
Up to 400 readings/s in fast mode (E-Series sensors)
GPIB/USB 2.0/10-100BaseT LAN, SCPI; optional 438A code compatibility
1 mW @50 MHz, ±0.4% (±1.2% over 0-55 °C)
1-1024 averages with auto-average (noise compensation)
0.001%-99.999% duty cycle; peak = measured / duty cycle
Offset -100~+100 dB (0.001 dB steps), limit alarming
Save/recall up to 10 instrument states
9 kHz ~ 110 GHz (sensor dependent)
-70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent)
Dual; expandable to 4 via optional USB host port
±0.02 dB (log) or ±0.5% (linear) plus sensor linearity
Normal 20 / x2 40 / fast 400 readings/s (E-Series, single channel)
1.00 mW (0.0 dBm) @50 MHz, factory ±0.4% (NPL traceable)
GPIB, USB 2.0, 10/100BaseT LAN (LXI-C); SCPI
Color LCD, single/split screen
Analog 0-1 V, BNC (channels A and B)
212.6 x 88.5 x 348.3 mm; 3.7 kg
90-264 VAC auto-select, 47-63 Hz (400 Hz at 110 VAC)
201 VGA+trigger+USB; C01/C02/C03 calibrator; 200 438A code compat; 908/909 rack kits
Source: Keysight official datasheets and listing materials; shipped specifications subject to the latest official release.
Need another file? Write to sales@jxby.tech
E-Series diode average power sensor: 10 MHz to 18 GHz, -70 ~ -20 dBm (
View details → Keysight N1914B EPM Series Dual-Channel Average Power Meter, DC-220GHz, -70 to +44dBm, ±0.02dB AccuracyNew-generation EPM-Series dual-channel average power meter: all averag
View details → Keysight V3500A Handheld RF Power Meter, 10MHz to 6GHz, -60dBm to +20dBm, Integrated SensorPalm-sized handheld RF power meter: built-in 10 MHz to 6 GHz sensor, -
View details →Send us the scenario, band and working method — we will respond with a recommendation within 48 hours.
Get a recommendation