87230: Calibration and routine verification

The 87230 specifies Power range of -50 to +20 dBm (87230); -60 to +20 dBm (87231/87232) and Data interface of USB 2.0 (TMC compatible). Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-05-01 has been reviewed against the site product master data and expanded with the specification highlights and method index for model 87230; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

The principal specifications of the 87230 follow the site product master data: Power range -50 to +20 dBm (87230); -60 to +20 dBm (87231/87232) and Data interface USB 2.0 (TMC compatible). Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that RF connector N-type (m) on 87230/87231; 3.5 mm (m) on 87232 matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Models and frequency87230: 9 kHz-6 GHz; 87231: 10 MHz-18 GHz; 87232: 50 MHz-26.5 GHz
Power range-50 to +20 dBm (87230); -60 to +20 dBm (87231/87232)
RF connectorN-type (m) on 87230/87231; 3.5 mm (m) on 87232
Data interfaceUSB 2.0 (TMC compatible)
Dimensions87230/87231: 46.2 x 35.6 x 142.6 mm; 87232: 46.2 x 35.6 x 135.4 mm
Options001 English option (labels and control program); JL calibration service with report
Series note87233 (50 MHz-40 GHz, 2.4 mm) is described on the 87233 series page
PositioningUSB continuous-wave power measurement
Related Instruments & Equipment
BB60C
BB60CView details →
VSG200
VSG200View details →
RFS44
RFS44View details →
References
  • Specifications: site product master data (model 87230)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)
87230 Model page →