N9961A: Automated integration and data logging

The N9961A specifies Frequency range of 5 kHz ~ 44 GHz and DANL of -137 dBm (>2 MHz-2.1 GHz, preamp off, spec); -153 dBm preamp on. Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-04-05 has been reviewed against the site product master data and expanded with the specification highlights and method index for model N9961A; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — N9961A
Instrument — N9961A
Frequency range5 kHz ~ 44 GHz
DANL-137 dBm (>2 MHz-2.1 GHz, preamp off, spec); -153 dBm preamp on
RBW / VBW1 Hz ~ 5 MHz

The principal specifications of the N9961A follow the site product master data: Frequency range 5 kHz ~ 44 GHz and DANL -137 dBm (>2 MHz-2.1 GHz, preamp off, spec); -153 dBm preamp on. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that RBW / VBW 1 Hz ~ 5 MHz matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Frequency range5 kHz ~ 44 GHz
DANL-137 dBm (>2 MHz-2.1 GHz, preamp off, spec); -153 dBm preamp on
RBW / VBW1 Hz ~ 5 MHz
Absolute amplitude accuracy±0.60 dB at 50 MHz (spec); ±0.90 dB >15 MHz-32 GHz
Input attenuator0 ~ 30 dB in 5 dB steps
Max safe input+25 dBm / 0.3 W / ±40 VDC
Real-time analysisOption 350: 1 MHz-44 GHz
Noise figureOption 356: 10 MHz-44 GHz
Frequency reference±0.7 ppm + aging; ±0.01 ppm GPS locked (Option 307)
Display/dimensions6.5-inch color LCD; 292.4 x 187.4 x 71.6 mm
Test portsNMD 2.4 mm test ports + SMA ref/trigger
Ordering options233 SA; 235 preamp; 236 interference; 350 RTSA; 351 IQA; 356 NF; 307 GPS; 310 power meter
Related Instruments & Equipment
N9961A
N9961AView details →
BB60C
BB60CView details →
VSG200
VSG200View details →
References
  • Specifications: site product master data (model N9961A)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)
N9961A Model page →