N1914A: Comparison with comparable models

The N1914A specifies Frequency range of 9 kHz ~ 110 GHz (sensor dependent) and Power range of -70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent). Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-01-28 has been reviewed against the site product master data and expanded with the specification highlights and method index for model N1914A; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — N1914A
Instrument — N1914A
Frequency range9 kHz ~ 110 GHz (sensor dependent)
Power range-70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent)
ChannelsDual; expandable to 4 via optional USB host port

The principal specifications of the N1914A follow the site product master data: Frequency range 9 kHz ~ 110 GHz (sensor dependent) and Power range -70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent). Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that Channels Dual; expandable to 4 via optional USB host port matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Frequency range9 kHz ~ 110 GHz (sensor dependent)
Power range-70 ~ +44 dBm (100 pW ~ 25 W, sensor dependent)
ChannelsDual; expandable to 4 via optional USB host port
Absolute accuracy±0.02 dB (log) or ±0.5% (linear) plus sensor linearity
Reading ratesNormal 20 / x2 40 / fast 400 readings/s (E-Series, single channel)
Power reference1.00 mW (0.0 dBm) @50 MHz, factory ±0.4% (NPL traceable)
Remote interfacesGPIB, USB 2.0, 10/100BaseT LAN (LXI-C); SCPI
DisplayColor LCD, single/split screen
Recorder outputAnalog 0-1 V, BNC (channels A and B)
Dimensions/weight212.6 x 88.5 x 348.3 mm; 3.7 kg
Line power90-264 VAC auto-select, 47-63 Hz (400 Hz at 110 VAC)
Ordering options201 VGA+trigger+USB; C01/C02/C03 calibrator; 200 438A code compat; 908/909 rack kits