Contact JXBY
Technical note

ZNA: Method index and measurement uncertainty

The ZNA specifies Frequency range of 10 MHz ~ 26.5/43.5/50/67 GHz (ZNA26/ZNA43/ZNA50/ZNA67) and Frequency resolution of 1 Hz per trace. Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-04-09 has been reviewed against the site product master data and expanded with the specification highlights and method index for model ZNA; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — ZNA
Instrument — ZNA
Frequency range10 MHz ~ 26.5/43.5/50/67 GHz (ZNA26/ZNA43/ZNA50/ZNA67)
Frequency resolution1 Hz per trace
Measurement bandwidth1 Hz ~ 1.5 MHz; up to 30 MHz with K17

The principal specifications of the ZNA follow the site product master data: Frequency range 10 MHz ~ 26.5/43.5/50/67 GHz (ZNA26/ZNA43/ZNA50/ZNA67) and Frequency resolution 1 Hz per trace. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that Measurement bandwidth 1 Hz ~ 1.5 MHz; up to 30 MHz with K17 matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Frequency range10 MHz ~ 26.5/43.5/50/67 GHz (ZNA26/ZNA43/ZNA50/ZNA67)
Ports2 or 4
Connectors3.5/2.92/2.4/1.85 mm (model dependent)
Frequency resolution1 Hz per trace
Measurement points1 ~ 100001
Measurement bandwidth1 Hz ~ 1.5 MHz; up to 30 MHz with K17
Impedance50 ohm
Dimensions/weight461.4 x 284.6 x 462.1 mm; 24 kg (2-port) / 29 kg (4-port)
Power supply100 ~ 240 V, 50/60/400 Hz
Operating temperature+5 °C ~ +40 °C
Calibration interval1 year
Ordering optionsZNA26/43/50/67 x 2/4 ports x connector type; ZNA-K17; application options
Related Instruments & Equipment
ZNA
ZNAView details →
BB60C
BB60CView details →
VSG200
VSG200View details →
References
  • Specifications: site product master data (model ZNA)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)
ZNA Model page →