4052: Calibration and routine verification

The 4052 specifies Analysis bandwidth of 10 MHz standard; options 40/200/400/600 MHz and 1.2 GHz and Phase noise of Better than -122 dBc/Hz at 10 kHz offset (1 GHz); -127 dBc/Hz with enhancement option. Using the ITU-R SM.1753 (spectrum occupancy measurement) method index, this note sets out specification limits, setup considerations and operating conditions; every value is quoted verbatim from the site product master data.

Record

The entry recorded in this section on 2026-07-16 has been reviewed against the site product master data and expanded with the specification highlights and method index for model 4052; no unverified external claims are introduced.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)
Instrument — 4052
Instrument — 4052
Analysis bandwidth10 MHz standard; options 40/200/400/600 MHz and 1.2 GHz
Phase noiseBetter than -122 dBc/Hz at 10 kHz offset (1 GHz); -127 dBc/Hz with enhancement option
Sweep points101-120001

The principal specifications of the 4052 follow the site product master data: Analysis bandwidth 10 MHz standard; options 40/200/400/600 MHz and 1.2 GHz and Phase noise Better than -122 dBc/Hz at 10 kHz offset (1 GHz); -127 dBc/Hz with enhancement option. Together they define the measurable range and resolving capability, and are the first conditions to check when assembling a test chain.

Following the ITU-R SM.1753 (spectrum occupancy measurement) method index, confirm that Sweep points 101-120001 matches the signal level under test, and record connections, ambient conditions and reference settings so the result remains reproducible.

High-tech concept application scene (AI-generated illustration)
High-tech concept application scene (AI-generated illustration)

In practice, start with a wide-span survey and then narrow resolution and bandwidth to re-check detail. Retain the original settings and observation log at each step rather than comparing values obtained under different conditions.

The product photographs retain the markings printed on the instrument housing; the scene background is illustrative and does not represent an actual test environment. The full specification table below is quoted verbatim from the master data without conversion, extrapolation or performance claims.

The related instruments section lists real, currently listed models in the same category for comparison on a common specification basis. The model page carries the complete parameter set and documentation entry points.

Full specifications (product master data)
Models and frequency4052A 2 Hz-4 GHz; 4052B -8 GHz; 4052C -13.6 GHz; 4052D -18 GHz
Models (cont.)4052E -26.5 GHz; 4052F -40 GHz; 4052G -45 GHz; 4052H -50 GHz
Analysis bandwidth10 MHz standard; options 40/200/400/600 MHz and 1.2 GHz
Phase noiseBetter than -122 dBc/Hz at 10 kHz offset (1 GHz); -127 dBc/Hz with enhancement option
DANL-154 dBm/Hz at 1 GHz; -165 dBm/Hz with preamp; -172 dBm/Hz with noise cancellation
Spurious-free dynamic range-75 dBc at 200 MHz bandwidth; -65 dBc at 1.2 GHz
Sweep points101-120001
Sweep timeUp to 16000 s; 1 microsecond minimum in zero span
Data interface10 Gigabit Ethernet for 1.2 GHz bandwidth data
Dimensions475 x 193 x 560 mm including handles and feet
Function optionsH16 phase-noise enhancement; H41 real-time spectrum; S10/S10H/S10F transient analysis; S12/S12B/S12M vector signal analysis
Related Instruments & Equipment
4052
4052View details →
BB60C
BB60CView details →
VSG200
VSG200View details →
References
  • Specifications: site product master data (model 4052)
  • Method index: ITU-R SM.1753 (spectrum occupancy measurement)