Contact JXBY
Technical Solutions

Low-Loss Material Dielectric Property Test Solution

0.4 GHz-170 GHz for high-accuracy complex permittivity measurement on low-loss materials, using a VNA with S-parameter modules, resonant cavities, fixtures and system software.

0.4 GHz–170 GHzHigh-accuracy complex permittivityMulti-mode cavity, multi-frequency pointsFive resonator methods
Material EM Parameter Testing

Solution Overview

Solution Overview

The low-loss material dielectric property test system covers 0.4 GHz to 170 GHz and measures the complex permittivity of low-loss materials with high accuracy. The system comprises a vector network analyser, S-parameter test modules, cavity fixtures, connecting cables and system software. Depending on the required frequency, the open coaxial cavity, split cavity, open cavity, perturbation cavity or cylindrical cavity can be selected. The system offers high accuracy, fast measurement and convenient operation; a multi-mode single-cavity technique allows dielectric measurement at multiple frequencies within a wide band in the same cavity.

Key Features

Open coaxial cavity · Split cavity · Open cavity · Perturbation cavity · Cylindrical cavity · System software · Dielectric property calculation

  • High measurement accuracy and fast measurement
  • Simple system configuration and easy operation
  • Straightforward measurement software with a high degree of automation

The open coaxial cavity method offers three cavity specifications — 0.8 / 2.45 / 4.2 / 6 / 7.6 GHz, 1 / 3 / 5 / 7 / 9 GHz and 2 / 6 / 10 / 14 / 18 GHz — selected to suit the requirement. The open coaxial cavity is convenient to operate and undemanding on sample preparation: the sample only has to be machined into a square plate at least 1 cm on a side with a smooth surface, and is placed on top of the cavity. The method is easy to run and achieves high-accuracy measurement at several frequencies within a band.

The split cavity has a symmetrical half-cylinder structure; a flat sample is placed between the two halves. Relative permittivity and loss tangent are calculated from the change in resonant parameters before and after loading the sample. The split cavity is a single-frequency cavity and can be customised to the required test frequency.

The open cavity test platform is an open structure offering an ultra-wide test band (12 GHz to 170 GHz) and an advantage in electrical loss tangent accuracy. Different open cavity configurations are available to suit different test frequencies.

Testing uses a cylindrical perturbation cavity fixture; this is a single-frequency measurement. Samples are long cylindrical or rectangular bars, and the test frequency can be customised to the requirement.

Testing uses a cylindrical cavity fixture with multi-frequency measurement. Samples are sheet-shaped and the TE0mn mode is used.

The test software measures permittivity, loss tangent and other electrical parameters of solid dielectric materials, and can perform automatic multi-frequency identification testing for some methods.

From the S-parameters of the empty cavity and the loaded cavity, the Q factor and resonant frequency of low-loss samples are identified and extracted, and the software computes results at multiple frequencies across the band.

Typical Applications

Low-loss dielectric characterisation of solid materials — where permittivity and loss tangent must be known accurately across a wide band, and the sample can be prepared as a flat plate, a bar or a machined ring according to the method selected.

System Architecture

Key Features

01

High accuracy, high speed

02

Multi-mode cavity for broadband multi-frequency testing

03

Simple configuration, easy operation

04

Low sample requirement: ≥1 cm square plate (open coaxial)

05

Resonators customised to required test frequencies

Typical Applications

Substrate & low-loss composite testing
Dielectric characterisation for filter / antenna materials
Broadband permittivity & loss measurement

Recommended Products

Related Solutions

Need This Solution Configured or Customized?

Send us the device under test, frequency range, sample size and site conditions. Our engineering team will provide an executable configuration during solution consulting and site planning.