1 GHz-500 GHz with test temperatures up to 1600 degrees C, measuring complex permittivity, complex permeability and reflectivity under high-temperature conditions.

The high-temperature electromagnetic parameter test system covers 1 GHz to 500 GHz, with some configurations reaching test temperatures of up to 1600 °C, and measures complex permittivity, complex permeability and reflectivity under high-temperature conditions. The system comprises a vector network analyser, heating equipment, high-temperature test fixtures and system software. Several fixture types are available to suit different frequencies and material types.
High-temperature cavity method · Waveguide transmission heating equipment · Bow-frame high-temperature reflectivity method · Bow-frame heating equipment · System software
The high-temperature cavity method covers 1 GHz to 110 GHz. For the open-cavity method the sample is machined into a flat plate and placed on the plane mirror; for the perturbation method it is machined into a rectangular or cylindrical bar and placed inside the fixture. After heating to the set temperature, the cavity data with the sample loaded and the empty-cavity data are measured with the vector network analyser, and the permittivity and loss of the sample at high temperature are calculated accurately and quickly. Optimised fixture design gives the system fast measurement and high accuracy.
This method covers 2.6 GHz to 40 GHz. The sample is machined into a rectangular block and placed inside the fixture. A calibration kit is used to complete two-port calibration following the system prompts, and the fixture with the sample is then installed and positioned. The software settings allow electromagnetic parameters to be acquired at different temperatures.
This method covers 1 GHz to 500 GHz. The sample is plate-shaped, and the heating platform provides wave-transparent cover insulation. The software allows material reflectivity to be acquired at different temperatures.
The system software supports the waveguide transmission line method, the cavity method and the bow-frame method, and controls the temperature equipment remotely from the host computer so that electromagnetic parameters can be measured at different temperatures. Functions include test-method selection with the corresponding parameter setup and calibration prompts; electromagnetic parameter calculation from the calibrated S-parameters, producing permittivity, permeability and electrical and magnetic loss tangents, with non-magnetic material testing and reflectivity derived from the electromagnetic parameters; tabular display of permittivity and loss tangent; and saving of results in text format.
The high-temperature electromagnetic parameter test system offers high accuracy over a wide band and is widely used to evaluate the electromagnetic properties of high-loss absorbing materials and low-loss wave-transparent materials under high-temperature conditions in aerospace and aviation equipment.
High-temperature resonator method: 1–110 GHz
Waveguide transmission method: 2.6–40 GHz
Bow-frame high-temperature reflectivity: 1–500 GHz
Remote temperature control via host PC
Precise temperature control, fast measurement
Send us the device under test, frequency range, sample size and site conditions. Our engineering team will provide an executable configuration during solution consulting and site planning.